Instalation package DiegoG3 - Diego G3 software -3.0.3.3
New instalation package version of DiegoG3 supportes gas controllers: 1.3x, 1.4x, 1.5x and 3.0x.
Changes for PC software 3.0.3.2 (full compatibility with gas controller 30F):
+ Translation modification.
+ Add and remove model points using keyboard.
+ Improved compatibilities with older gas controlers version (1.4x, 1.5x).
+ More precise possibilities of setting the "Earlier valves opening time" parameter to 10 seconds.


Changes for PC software 3.0.3.2 (full compatibility with gas controller 30F):
+ Added simple and advanced view.
+ Improved "Set model" function on Map tab.
+ Improved compatibilities with older gas controlers version (1.4x, 1.5x).

Changes for PC software 3.0.3.1 (full compatibility with gas controller 30F):
+ New function: Enrichment during cut-off about injection _ [ms] if RPM< _.
+ New function: Correction when injection system is changed (Mazda).
+ Added button "Set model" on Map tab (function automatically adjust model regarding to collecting points).
+ Added message that clearing gas map is required when model is writing.
+ New mechanism for injection system detection.
+ Save to file and load from file petrol map template.
+ Moving model points by keyboard is available.
+ Improved Adaptaion mechanism.
+ Improved Determining working pressure mechanism.
+ Improved emergency start on gas.
+ Improved fuel overlapping (petro-gas) mechanism (always when system is switching to gas).
+ Improved Gas injectors heating mechanism.
+ Improved nozzles sugestion mechanism.
+ Improved autocalibration mechanism.
+ "RPM sound" active sounds when Tred>40Cdeg. (min temperatre for collecting map points).
+ On tab Calibration reducer temperature is displayed on red when Tred<40Cdeg. (min temperatre for collecting map points).
+ Notification about possibility of updating the controller (to the most recent firmware).
+ New program manual.

Changes for PC software 3.0.2.4 (full compatibility with gas controller 30E):
+ Solved problem with function "Recalculate model".
+ Improved compatibilities with older gas controlers version (1.4x, 1.5x).

Changes for PC software 3.0.2.3 (full compatibility with gas controller 30E):
+ Added languages: English, Russian, Lithuanian, Czech.
+ Recorder tool improved.
+ Added update file: 30C-20090608.upg.

Changes for PC software 3.0.2.2 (full compatibility with gas controller 30E):
+ Emergency start on gas improved.
+ Adaptation mode improved.
+ Languages corrections.
+ Improved compatibilities with older gas controlers version (1.4x, 1.5x).
+ Added dispay with update file info.
+ Adaptation option moved to tab Calibration (F4)\Modeling\Adaptation.
+ Corrections options (for Tgas and RPM) moved to tab Calibration (F4)\Modeling\Corrections - also for older gas controler
versions.

Changes for PC software 3.0.2.1 (full compatibility with gas controller 30D):
+ !!!New installation package contains software for gas ECU in version 1.3x, 1.4x, 1.5x, 3.0x.!!!

+ Changes in configuration settings detection mechanism.
+ Added pressure configuration for option 'Control pressure during cut-off.
+ For switching conditions: Switching to PETROL with automatic return to GAS: function 'Tgas<' [Low gas temp.] is changed to 'Tgas< and Load (Petrol)>' [Low gas temp and high Load (Petrol)].
+ Parameters 'Working pressure' and 'Petrol injection time on petrol when idle (no load)' moved from 'Configuration wizard\Installation' to 'Calibration\Modeling'.
+ Improved Autocalibration procedure.
+ Improved Working pressure meruring function.
+ Added gas injectiors test.
+ Drawing template line on petrol map after collecting enough petrol points.
+ Added adaptation mechanism for based RPM class.
+ Added model trace.
+ Added possibiliby of changing corection type for Tgas and RPM.
+ Added firmware update function (menu Device).

Changes for PC software 3.0.1.3:
- Correction for display Load regarding to engine injection system type
- Add to instalation package Win Vista driver for USB interface
- New PC software manual
- Solved problem with writing defaut settings for locked device
- Changing for display trouble codes

Changes for PC software 3.0.1.2:
- Translation corrections
- Add gas injectors: RAIL 2ohms and VALTEK 2ohms
- More precise possibilities of setting the "Time for switching a single emulator" parameter: 0; 0,2; 0,4; 0,6; 0,8; 1; 2; 3; 4; 5 (for gasECUs series 1,4 i 1,5 and 30)
- Show vacuum on Calibration pages

Changes for PC software 3.0.1.1 and gasECU 30C:
- New option "RPM wire not connected"
- Add gas injetors: RAIL IG3(E2) i (E3)
- New option "Gas injectors heating" for Tred
- New option "Fuel overlap (petol-gas)" with configurable number of cycles and gas injection time
- New option Switching to PETROL with automatic return to GAS when Tred to low and high load.
- New option "Gas pressure control during cut-off"
- New option "Use model for idle"
- Function "Set new model" for automatic modelling regarding to ilde points.
- Reset button on Recorder page
- More improved Autocalibration procedure

18,7 MBZIP
Version 1.3 Akme+USBDriver-1.3.2.6-v1.3 2,8 MB ZIP
DIEGO-1.2.6.9 v1.2 1 MB ZIP

USB interface driver 1,55 MB ZIP
USB interface driver for Windows Vista 1,7 MB ZIP

BingoM 4.03 0,4 MB ZIP
BingoS 3.08 0,7 MB ZIP

Diagnoskop KME 1.69.11 mini version 1,76 MB RAR
Diagnoskop KME 1.69.12 14,6 MB ZIP



Infoline & technical support for foreign and mobile connections: 0048 422 999 139

*From Polish landline call 0801 563 563 or 0801 KME KME
KME Poland - Teresy 103a, PL-91-222 Lodz, tel. +48 (42) 6110026, fax +48 (42) 6118252, http://www.kme.com.pl
navi-> [HOME]=> About us: history, certificates, contact. Products: autogas, diagnostics, other. Documentation: software, manuals, presentations.